How to Read a Duct Leakage Test Report (2026 Guide)
Updated October 21, 2026
Written by Rachid
Commercial Refrigeration and Air Conditioning Technician
A duct leakage report should help you understand what was measured, what needs repair, and how the completed work will be checked. A number such as “240 CFM25” is useful only when the report explains its test conditions and scope.
Quick answer: Identify the tested system, measurement type, units, pressure, and included components. Compare equivalent before-and-after tests. Then request a written repair scope and verification plan. A percentage reduction in measured leakage is not the same as that percentage reduction in energy bills.
First, Identify Which Test You Received
| Report item | Meaning | Question to ask |
|---|---|---|
| Total duct leakage | Leakage from the tested duct system to both inside and outside the enclosure | Which system and components were included? |
| Duct leakage to outside | Leakage communicating beyond the conditioned enclosure | Where is the enclosure boundary? |
| CFM25 | Test airflow in cubic feet per minute at a 25-pascal pressure difference | Which test procedure was followed? |
| ACH50 | Building-enclosure air changes per hour at a 50-pascal pressure difference | Which building volume was used? |
CFM25 describes airflow needed to maintain the test pressure. It is not automatically the leakage rate during ordinary HVAC operation. Where multiple duct systems exist, identify each system separately. The report should also state whether the air handler was included.
An unconditioned attic or crawlspace may be “outside” the enclosure even though it is within the building’s overall structure. Ask the tester to explain the boundary rather than assuming every basement is inside it.
Technical reference: Building America Solution Center: Duct Leakage Tests.
A Blower-Door Result Answers a Different Question
A blower-door test measures building-enclosure leakage. CFM50 expresses test airflow at 50 Pa; ACH50 relates that airflow to the tested volume. Neither is the home’s ordinary ventilation rate or a stand-alone duct-leakage result.
A blower door may be used alongside duct-testing equipment for certain procedures. Ask the provider to label the separate findings clearly. See the Building America enclosure-testing guide.
Read Before-and-After Numbers Fairly
Before accepting an improvement claim, ask whether the two tests used the same system, pressure, measurement type, and scope. Request an explanation of any changed conditions.
Illustrative calculation—not actual project data
Before: 240 CFM25 total leakage
After: 80 CFM25 total leakage
Reduction: 240 − 80 = 160 CFM25
Percentage reduction: 160 ÷ 240 × 100 =
approximately 66.7%
Assuming comparable tests, measured leakage fell by about two-thirds. This calculation does not establish a passing result or predict a 66.7% reduction in utility bills.
If a proposal includes a savings forecast, request its assumptions separately. Ask what information about the home and its operation was used and whether the figure is an estimate, a target, or a contractual commitment.
What Does a “Passing” Result Mean?
Ask the provider to identify the exact requirement being applied: the administering program or authority, applicable version, test stage, units, and calculation basis. Request the relevant written criterion if compliance is part of the project.
For both U.S. and Canadian projects, ask whether testing is diagnostic, part of a contractor’s quality-control process, or required by a specific permit or incentive program. A threshold printed on a general sales brochure is insufficient to explain your project’s obligations.
If a percentage or floor-area-normalized result appears, ask for the denominator and calculation. Keep the original measurement alongside the calculated figure so a second reviewer can follow the report.
Turn the Report Into a Defined Repair Scope
ENERGY STAR recommends a contractor who inspects the full duct system, addresses damaged or disconnected sections, evaluates supply-and-return balance, and checks airflow after repairs. Its guidance also calls for combustion-safety evaluation where gas- or oil-burning appliances are involved.
Use that guidance to ask what your proposal actually includes rather than assuming every service package contains the same work.
| Proposal item | What to request in writing |
|---|---|
| Identified defects | Locations, observations, and supporting photographs where available |
| Physical repairs | Which disconnected, damaged, or restricted sections will be corrected |
| Sealing work | Areas treated, proposed method, materials, and exclusions |
| Access and restoration | Responsibility for openings, finishes, and disturbed insulation |
| Verification | Post-work testing, reporting, airflow assessment, and applicable safety checks |
| Unmet target | What happens if the agreed result is not achieved |
Reference: ENERGY STAR: Hiring a Duct Improvement Contractor. For bundled equipment work, use our HVAC quote-comparison checklist to separate responsibilities and costs.
Keep Your Comfort Complaint in the Scope
If your main concern is a cold bedroom, write that concern into the service request. Ask how the contractor will determine whether the proposed work addresses it and what will be assessed afterward.
A lower leakage number alone does not demonstrate that every room received the intended airflow. Our uneven room-temperature guide helps organize observations for that discussion.
Sealing, Cleaning, and Replacement Are Separate Decisions
Cleaning removes material from duct surfaces. Leak sealing addresses unintended air paths. Interior coatings intended to encapsulate material are another procedure. The EPA’s duct-cleaning guidance distinguishes these purposes.
Ask what “duct treatment” means in the proposal and why each operation is recommended. See our duct-cleaning guide for that separate service.
If complete replacement is proposed, request evidence explaining why repair or sealing is insufficient. Use our existing ductwork repair-or-replacement guide to compare the proposed scope.
Testing and work-site safety: Leave pressure testing and internal equipment work to qualified providers. Ask how they will address combustion safety and suspected hazardous materials. Do not disturb suspected asbestos-containing insulation or duct materials.
Frequently Asked Questions
What if my report only says “ducts are leaky”?
Ask whether that is an inspection observation or a measured result. For a test, request the method, units, pressure, scope, and complete report.
Can I compare two contractors’ percentages?
Only after understanding how each percentage was calculated. Request the underlying measurements and the basis of comparison.
Should I accept a verbal promise to retest?
Have the verification method, deliverable, and responsibility included in the written proposal before work begins.
Which documents should I keep?
Keep the original report, agreed scope, photographs, final test report, invoice, and warranty information together. These make follow-up and second opinions easier.
Rachid is a Morocco-based technician with a diploma in commercial refrigeration and air conditioning and approximately nine years of hands-on experience. This guide explains homeowner report-review questions; it does not certify a test, establish a local compliance threshold, or replace an on-site assessment.
Comments